Home / Coffee knowledge / Espresso and brewing temperature: how can you measure it at home?
    Espressomaschinen
    Espresso und Brühtemperatur: wie könnt ihr zu Hause messen?

    Espresso and brewing temperature: how can you measure it at home?

    In our last post, we tested different espresso brewing temperatures and their influence on taste. Here we show you how and where the espresso brewing temperature is measured, and how you can measure the temperature of your machine at home.

    The perfect brewing temperature for espresso is between 91° and 95°. For a darker roast, we recommend the range of 91° to 93°. For lighter roasts we recommend 93° to 95° espresso brewing temperature.

    Try this at home sometime, set different brewing temperatures and check sensorially what tastes best to you personally. The question here, however, is where exactly we measure, and how precise it all is.

    Espresso and Brewing Temperature – Much to Discuss

    Ever since I've been dealing with the subject of coffee, brewing temperature is always worth a long conversation. Different brewing systems and brew group designs significantly change the consistency and influence of temperature. So it often lacks clear statements about what spectrum the optimal brewing temperature lies in.

    Nevertheless, or precisely because of this, we have taken on this topic and first examined the sensory change and the strength or extraction under the microscope. Rightly so, the blog and the comments on the YouTube video about it were followed by the questions:

    • where do you measure the temperature?
    • how consistent is such a machine?
    • how precise are these measurements?

    To answer these questions, we must first understand the design of boilers and brew groups and their influence on temperature.

    Espresso Brewing Temperature in Thermoblock Machines

    A thermoblock heats the water as it flows through a tube within the block. This also means that in the case of small thermoblock systems, the inlet temperature is crucial.

    Fresh tap water is usually cooler than water that has been sitting in the machine's tank for a while and has reached room temperature. The two water temperatures are different and must be heated for different lengths of time. Thus we end up again with different brewing temperatures in this case.

    We recommend always using fresh water to keep the starting conditions consistent. The larger the thermoblock, the fewer fluctuations you can expect. With sophisticated systems, as we see with the Decent Espresso Machine, the thermoblock performs more consistently than a boiler system. This works because the brew group is preheated by an additional heater and numerous temperature sensors control the water supply.

    With the thermoblock, measurement is done with a thermostat that often switches on and off in the 5-6 degree range. For example, it starts heating at 104°C and stops at 110°C. Temperature fluctuations can occur here as well.

    The temperature measured is the temperature in the block and not the actual brewing temperature. Depending on the design, this is then between 87°C and 93°C.

    Caution – Too Cold Brewing Temperature in the Thermoblock When…

    when you flush the group just before extraction. Because: before extraction, the thermoblock remains at approximately 104°C. When you start the brew and at that moment the boiler heater kicks in, you'll start the brew at approximately 87°C and end up too hot. That's why we recommend flushing thermoblock machines immediately after removing the portafilter and thus before grinding, so the thermoblock can heat up again. Thermoblock machines are generally too cold rather than too hot.

    Brewing Procedure for Thermoblock Machines

    1. Remove the portafilter
    2. Briefly flush the group, short water extraction
    3. grind and fill the portafilter
    4. extract

    After step two, the thermoblock heats up quickly and you achieve the higher brewing temperature.

    Thermostat and Pressostat Instead of PID

    In almost all boiler machines without temperature control (PID), the temperature is regulated via a mechanical thermostat or pressostat.

    The Thermostat

    Let's start with the thermostat, as this is rather rare and usually installed in cheaper machines. As soon as the boiler cools down slightly, it signals the heater to heat again. Since we fundamentally have much more water in a boiler than in a thermoblock, boiler machines are significantly more consistent in temperature. The thermostat also regulates the temperature in the approximately 5-degree range.

    The Pressostat

    Somewhat more precise, and therefore also installed in most dual boilers without PID, is the pressostat. It also sends the signal to heat to the heater, but regulates this via pressure. With both methods, measurement is taken in the steam area of the boiler.

    With an installed boiler of usually 1.5 to 1.8 liters capacity, the temperature fluctuates somewhat with both systems. With the functioning of a so-called heat exchanger, the recessed cylinder in a classic dual boiler, temperature fluctuations stay within limits. Adequate flushing before brewing also helps here to reduce the temperature of the thermo-siphon system (design of a Faema E61 brew group, in which water circulates permanently) before the brew group, so you don't extract the coffee with too hot a temperature, making it more bitter than it actually would be.

    Here too, the principle applies: the larger the boiler, the more consistency. With a 3-liter boiler, there is much more water that loses significantly less temperature, especially during extraction. Also at the moment when the pump pumps cold water from the water tank into the heat exchanger. The results in the cup are thus much more consistent. With the Basilea with PID and a 3-liter boiler, we measured temperature fluctuations of less than 0.4 degrees – that's world championship level!

    Where Do We Measure on Machines with Temperature Control?

    There are major differences between dual boilers with PID and dual or multi-boilers. How these machines are structured and how they work, we discussed in detail in this post.

    Dual Boiler with PID

    Let's take the next step in the price segment and move to dual boilers with PID. Now we no longer measure mechanically via pressostat or thermostat, but via a sensor. This allows precise measurement and precise control of the heater. Often, heating systems in dual boilers without PID either heat fully, or not at all. Once a sensor is installed, the heater in the boiler maintains more consistent temperature, either through full heating or targeted heating bursts.

    Measuring PID Correctly

    Measurement is then taken in the steam area. That's why with PID machines you always have to convert the displayed temperature according to the operating instructions.

    An example: 124°C displayed boiler temperature can correspond to a brewing temperature of approximately 92.5°C. But always consult your machine's operating instructions, as this varies from manufacturer to manufacturer.

    Even with PID devices, we would recommend flushing directly before brewing, as the water can heat up very strongly in the brew head here as well, and you thus start the brew with a very hot temperature.

    Dual or Multi-Boiler

    With luxury models featuring dual or multi-boilers, we measure separately in each boiler. This enables a very high steam temperature, independent of a differently set brewing temperature. But here too, the principle applies: the larger the boiler, especially the coffee boiler, the more consistently you can brew.

    The new systems in the professional catering sector go even one step further. To achieve the consistency of less than 0.5-degree temperature fluctuation during brewing, today the brew groups are actively heated to make them even more consistent. This ends up with a multi-boiler machine with two coffee boilers per brew group and active boiler heating. The fluctuations are thus minimized to 0.1 to 0.2°C and are therefore negligible.

    Measuring Espresso Brewing Temperature at Home

    To measure the brewing temperature on your own machine, you need a temperature probe that you insert deep into a portafilter outlet. Then you start an extraction without coffee – it's important that you always do this with a hot portafilter. There are also portafilters with built-in thermometers. We use these for example for our tests, as this also creates a resistance against the pump.

    If you want to do the measurement with coffee, the water naturally loses temperature significantly at the beginning of brewing, since the coffee is at room temperature in the portafilter. You'll notice a significant rise during brewing.

    But please don't forget to drink your coffee while you're busy measuring.

    What do you think?

      Which machine should we test next?

      Espresso machine or grinder: Tell us what should be next on our test bench. We read every request.

      We only use your email to follow up on your request. You'll only receive the newsletter if you check the box and confirm. Privacy Policy